Hazard Lamps Malfunction > < DTC C0297

Reading Lamps Malfunction

Diagnostic Instructions

•  Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
•  Review Strategy Based Diagnosis for an overview of the diagnostic approach.
•  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Diagnostic Fault Information



Circuit


Short to Ground


Open/High Resistance


Short to Voltage


Signal Performance


Reading Lamps B+


1, 2, 3


1


-


-


Reading Lamps Ground Terminal 6


-


1


1


-


1. Reading Lamps Always OFF

2. Sunshade Lamps Always OFF

3. Instrument Panel Compartment Lamp Always OFF

 

Circuit/System Description

The body control module (BCM) supplies the dome/reading lamps, sunshade and instrument panel compartment lamp with battery voltage. When switching on the following components the concerning lamps will illuminate:

•  Dome/reading lamps
•  Dome/reading lamps - row
•  Sunshade - left front
•  Sunshade - right front
•  Instrument panel compartment lamp

Reference Information


Schematic Reference

Interior Lights Schematics


Connector End View Reference

Component Connector End Views


Description and Operation

Interior Lighting Systems Description and Operation


Electrical Information Reference


Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification

Ignition ON, switch the dome/reading lamps or dome/reading lamps - row ON and OFF while observing the lamp. The concerning reading lamp should illuminate when switched ON.

Circuit/System Testing

Reading Lamps Circuit Malfunction

1. Ignition OFF, disconnect the harness connector at the appropriate reading lamp.
2. Disconnect the negative terminal of the C1 Battery.
3. Test for less than 5 Ω between the ground circuit terminal 6 and ground.
If greater than the specified range, test the ground circuit for an open/high resistance.
4. Reconnect the negative terminal of the C1 Battery.
5. Ignition ON, test for greater than 11 V between the 12 V circuit terminal 1 and the ground circuit terminal 6.
If less than the specified range, test the circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K9 Body Control Module.
6. If all circuits test normal, test or replace the E37A Dome/Reading Lamps or E37B Dome/Reading Lamps - 2nd Row.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

•  Control Module References for BCM replacement, setup, and programming

Hazard Lamps Malfunction > < DTC C0297