Brake Pedal Position Sensor Calibration
Calibration Criteria
Note: Do not apply the
brake pedal during the brake pedal position sensor calibration
procedure. Any movement of the brake pedal during this procedure
will cause the calibration procedure to fail. If this occurs, the
brake pedal position sensor calibration must be repeated.
Brake pedal position sensor calibration must be performed after
the brake pedal position sensor or body control module (BCM) have
been serviced. The calibration procedure will set the brake pedal
position sensor home value. This value is used by the BCM to
determine the action of the driver applying the brake system and to
provide this information to the vehicle subsystems via serial
data.
Calibration Procedure
1. |
Apply the parking
brake. |
2. |
Place the transmission in the
PARK position for automatic transmission or NEUTRAL position for
manual transmission. |
4. |
Clear all BCM DTCs before
proceeding. |
5. |
Navigate to the
Configuration/Reset Functions menu of the BCM. |
6. |
Select the Brake Pedal
Position Sensor Learn procedure and follow the directions displayed
on the screen. |
|